loading page

Mushroom thrombus” A unique post transcatheter mitral valve replacement (Valve in valve) early complication
  • Hemant Chaturvedi,
  • Ravinder Rao
Hemant Chaturvedi
Eternal Hospital and Research Institute

Corresponding Author:[email protected]

Author Profile
Ravinder Rao
Eternal Heart Care Center
Author Profile

Abstract

The incidence of prosthetic valve thrombosis post transcatheter mitral valve replacement remains largely unknown. Although it may occur more frequently than after transcatheter aortic valve replacement, only isolated cases have been reported up to now. This unique large mushroom thrombus post TMVR case is first of its kind reported ever. 3D transesophageal as well as transthoracic echocardiography play very important role in early diagnosis and for treatment decision