Proarrhythmic Effect of RF ablation on the Right Ventricular Moderator Band
  • Jonathan Willner,
  • Parth Makker,
  • Roy John
Jonathan Willner
Northwell Health
Author Profile
Parth Makker
Lenox Hill Hospital
Author Profile
Roy John
North Shore University Hospital
Author Profile

Abstract

The right ventricular moderator band (MB) is increasingly being recognized as a source for PVCs and PVC-mediated ventricular fibrillation. Monomorphic PVCs, non-sustained monomorphic VT and ventricular fibrillation are all documented arrhythmias originating from the MB. The benign PVCs usually have a coupling interval in excess of 400 msec. When PVCs trigger VF, coupling intervals are typically short, less than 300 msec. We report here a case of long-standing frequent monomorphic PVCs with a coupling interval of > 400 msec from the right ventricular distal conduction system embedded in the moderator band that progressed to non-sustained ventricular tachycardia. Following suppression of the arrhythmia with RF ablation, the arrhythmia recurred with PVCs at a shorter coupling interval (<300 msec), with frequent repetitive non-sustained polymorphic VT and triggering of sustained ventricular fibrillation. The use of a cryoballoon to ablate over the course of the moderator band resulted in complete and durable suppression of ventricular arrhythmias.