Chen-Xi Jiang

and 9 more

Background: The anterior and lateral position of the anterolateral papillary muscle (ALPM) has found to be reached with better catheter stability and less mechanical bumping via the transseptal (TS) compared to the retrograde aortic (RA) approach. Aim: To compare the TS and RA approaches on mapping and ablation of ventricular arrhythmias (VAs) arising from ALPMs. Methods: Thirty-two patients with ALPM-VAs undergoing mapping and ablation via the TS approach were included and compared with 31 patients via the RA approach within the same period. Acute success was compared, as well as other outcomes including misinterpreted mapping results due to bumping, radiofrequency (RF) attempts, procedural time and success rate at 12 months’ follow-up. Results: Acute success was achieved in more cases in the TS group (96.4% vs 72.0%, P=0.020). During activation mapping, bump-provoked premature ventricular complexes (PVCs) misinterpreted as clinical PVCs were more common in the RA group (30.0% vs 58.3%, P=0.036), leading to more RF attempts (3.5±2.7 vs 7.2±6.8, P=0.006). Suppression of VAs were finally achieved in the unsuccessful cases by changing to the alternative approach, but the procedural time was significantly less in the TS group (90.0±33.0 vs 113.7±41.1min, P=0.027) with less need to change the approach, although follow-up success rates were similar (75.0% vs 71.0%, P=0.718). Conclusion: A TS rather than RA approach as the initial approach appears to facilitate mapping and ablation of ALPM-VAs, specifically by decreasing the possibility of misleading mapping results caused by bump-provoked PVC, and increase the acute success rate thereby.

Xin Su

and 15 more

Background: Atrial fibrillation (AF) is common in abdominal solid organ transplant recipients and a cause of morbidity and mortality in this population. However, the outcomes of catheter ablation (CA) in transplant recipients with AF remain unclear. This study aimed to elucidate the outcomes of CA in renal and hepatic transplant recipients. Methods and Results: Between 2015 and 2019, 14 transplant recipients (9 with kidney transplantation and 5 with liver transplantation) were enrolled from among 10,741 AF patients and underwent CA at Anzhen Hospital. Another 56 patients matched by age, sex and AF type were selected as the control group (4 controls for each transplant recipient). During a mean follow-up of 30.0±13.3 months after the initial procedure, 10 (71.4%) of the transplant patients, compared to 41 (73.2%) of the control patients, remained free from AF recurrence(P=1.000). A repeated procedure was performed in 1 transplant patient and in 6 control subjects. Consequently, 11 (78.6%) of the transplant patients, compared to 46 (82.1%) of controls, were in sinus rhythm after the repeated ablation (P=0.715). Notably, Kaplan–Meier analysis did not demonstrate any significant differences in the atrial arrhythmia-free rate after the initial and repeated procedure between the two groups. Vascular complications were identified in 1 transplant patient and 2 control subjects, while no life-threatening complications were observed in either group. There was no transient allograft dysfunction in transplant recipients after CA. Conclusion: CA is safe and effective in abdominal solid transplant recipients, and may be an optimal therapeutic strategy for this group.