Yasunobu Yamagishi

and 9 more

Background: In terms of the pulmonary vein (PV), atrial fibrillation (AF) patients have a shorter effective refractory period (ERP) and a larger dispersion of the ERP than patients without AF. Although the frequency of AF from the superior vena cava (SVC) was the highest among non-PV foci, the characteristics of the ERP in the SVC (SVC-ERP) were unclear. The purpose of this study was to elucidate the relationship between SVC-ERP and the inducibility of AF after pulmonary vein isolation (PVI). Methods and Results: Consecutive 28 patients who underwent PVI were included. After successful PVI, the SVC-ERP was measured at three positions in SVC. Rapid electrical stimuli were delivered at the shortest SVC-ERP to induce AF. Patients in whom AF was induced were assigned to the SVC-induced group (SIG) and the remaining patients were the non-SVC-induced group (non-SIG). The size of the SVC sleeve was evaluated using three-dimensional electroanatomic mapping. The SIG had a significantly shorter average SVC-ERP (236.0±25.2 vs. 294.8±36.8 ms, p<0.001), while SVC-ERP dispersion was not significantly different (30.0±25.4 vs. 33.3±20.1 ms, p=0.56). Although the longer SVC diameter was significantly longer in the SIG (27.4±4.3 vs. 22.9±4.6 mm, p=0.03), the SVC-ERP was significantly associated with pacing inducibility of AF after adjustment for the longer SVC diameter (odds ratio: 0.96 [1-ms increments], p=0.01). Conclusions: The SIG had a shorter SVC-ERP, while the dispersion was not significantly different between the two groups. The SVC-ERP can be one of the mechanisms of arrhythmogenicity for AF originating from the SVC.

Keita Tsukahara

and 22 more

Introduction: An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding the effectiveness of the ICD, targeted VT is defined based on the tachyarrhythmia cycle length. However, variation of the RR interval variability of VTs does occur. A few studies reported on VT characteristics and effects of ICD therapy according to RR interval variability. This study aimed to identify the clinical characteristics of VTs and effects of ICD therapy according to RR interval variability. Methods: We analyzed 821 VT episodes in 69 of 185 patients treated with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as regular or irregular based on RR interval variability. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. Reproducibility of the RR interval variability in one VT episode and within an individual with recurrent VT episodes was evaluated. Results: Regular VT was significantly more successfully terminated than irregular VT by ATP therapy. There was no significant difference in shock therapy or VT acceleration, irrespective of the variability of the VT cycle length. Spontaneous termination of VT occurred significantly more often in irregular than in regular VT. Reproducibility of RR interval variability in an episode and individual was 89% and 73%, respectively. Conclusion: ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs is reproducible.